High Intensity Ultraviolet Light

Image
The 400 watt metal halide bulbs or "super light" can be found in some facilities. This super bright will provide adequate lighting over an area of up to ten times that covered by the 100 watt bulb. Due to their high intensity, excessive light reflecting from the surface of a component is a concern. Moving the light a greater distance from the inspection area will generally reduce this glare. Another type of high intensity light available is the micro - discharge light. This particular light produces up to ten times the amount of UV light conventional lights produce. Reading of up to 60,000 uW/cm2 at 15 inches can be achieved. Determining whether a magnetic field is of adequate strength and in the proper direction is critical when performing magnetic particle testing. As discussed previously, knowing the direction of the field is important because the field should be as close to perpendicular to the defect as possible and no more than 45degrees from normal. Being able to e...