Distance Amplitude correction (DAC) in ultrasonic inspection.

Image
Acoustic signals from the same reflecting surface will have different amplitudes at different distances from the transducer. Distance Amplitude correction (DAC)  provides a means of establishing a graphic reference level sensitivity as a function of sweep distance on the A - scan display. The use of DAC allows signals reflected from similar discontinuities to be evaluated where signal attenuation as a function of depth has been correlated. Most often DAC will allow for loss in amplitude over material depth  (time), graphically on the A - scan display but can also be done electronically by certain instruments. Because near field length and beam spread vary according to transducer size and frequency, and materials vary in attenuation and velocity, a DAC cure must be established for each different situation. DAC may be employed in both longitudinal and shear modes of operation as well as either contact or immersion inspection techniques. A distance Amplitude correction curve ...